MM II 24
Axis Update Mode
Command Sequence: <mode command><update value>
ASCII command
mode command
update value
G
<SP> to z
Axis Update Mode is an adjunct to Remote Request, Stream and Switch Stream modes,
particularly useful if using a grid on the tablet and you want reports sectioning the grid
intersection points.
The points issued are:
Point
Report
Description
1
2
3
4
No
5
6
(0,0)
(10,0)
(10,10)
(20,10)
point is
(30,10)
(30,20)
Reference point, the first point collected in Axis Update Mode.
X update was met. Y was not. Last Y value repeated.
Y update was met. X was not. Last X value repeated.
X update was met. Y was not. Last Y value repeated.
issued between points 4 and 5 because the same report is not issued
consecutively.
X update was met. Y was not. Last Y value repeated.
Y update was met. X was not. Last X value repeated.