CR Configuration: Self-Test Report
A
D
PR
CA
T
Analog circuitry test; pass = 1, fail = 0
Digital circuitry test; pass = 1, fail = 0
Stylus/cursor proximity; stylus/cursor in-prox = 1, stylus/cursor out-of-prox = 0
Tablet calibration; pass = 1, fail = 0
Total test result (based on A, D and CA); pass = 1, fail = 0
Bit Pad One and Two configurations: If the test result is a Hex 17 or 1F, or equivalent, the
tablet passed the tests. Any other result means that the tablet failed.
CR configuration: If the test result is a Hex 9F or 97, or equivalent, the tablet passed the
tests. Any other result means that the tablet failed.